I-SOI-10
SOIC Installation TJ-70 Hot Air

1. Start with a heater temperature of 482°C (900°F) and adjust as necessary.
2. Install tip into ThermoJet® Handpiece using Tip Tool.
3. Apply a small bead of solder paste along the land pattern using a dispenser. (A)
4. Position component onto lands using a HandiPik® or tweezers. (B)
5. Starting at MINIMUM,adjust pressure output (on power supply) so hot air scorches a tissue from approximately 0.5cm (0.2”) away. (C)
6. Direct hot air over component with tip at a distance of 2.5cm (1.0”) to predry solder paste. (D)
7. When pre-drying is observed (paste has dull, flat appearance), bring tip closer (0.5cm [0.2”]) and slowly move tip along each row of leads to form proper solder fillets. (E)
8. Return ThermoJet® to its Tip & Tool Stand.
9. Clean, if required, and inspect.
PACE SensaTemp® or Intelliheat® Power Supply
TJ-70 ThermoJet®
Flat End Tip (See Chart on Back)
Pik & Paste Liquid Dispensing System
Tip Tool
HP-65 HandiPik®
Tweezer
Manual Solder Paste Dispenser
Solder Paste
Paste Dispense Needles
Cleaner
Product Image | Dimensions | Part Number |
---|---|---|
![]() |
1121-0371-P1 | |
![]() |
0.060" I.D. | 1121-0366-P1 |
![]() |
Diameter: 0.060" I.D. | 1121-0338-P1 |
![]() |
Dimension A: A = 4.32mm (0.17") | 1121-0330-P1 |